Exit
1011 Athens Street
Gainesville, GA 30501 USA
Gainesville Industrial Electric
AEHGTK, TEFC, NEMA, Premium Efficiency, Medium Voltage
Unit of Measure
Items
KG Global Series TEFC NEMA Premium Efficiency Medium Voltage Motors

KG Global Series 100 Horsepower (hp), 3600 Revolutions Per Minute (rpm), and 444TS Frame TEFC NEMA Premium Efficiency Medium Voltage Motor

KG Global Series TEFC NEMA Premium Efficiency Medium Voltage Motors

KG Global Series 100 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 444T Frame TEFC NEMA Premium Efficiency Medium Voltage Motor

KG Global Series TEFC NEMA Premium Efficiency Medium Voltage Motors

KG Global Series 100 Horsepower (hp), 1200 Revolutions Per Minute (rpm), and 444/5T Frame TEFC NEMA Premium Efficiency Medium Voltage Motor

KG Global Series TEFC NEMA Premium Efficiency Medium Voltage Motors

KG Global Series 100 Horsepower (hp), 1200 Revolutions Per Minute (rpm), and 444/5T Frame TEFC NEMA Premium Efficiency Medium Voltage Motor

KG Global Series TEFC NEMA Premium Efficiency Medium Voltage Motors

KG Global Series 100 Horsepower (hp), 900 Revolutions Per Minute (rpm), and 444/7T Frame TEFC NEMA Premium Efficiency Medium Voltage Motor
Description N/A AEHGTK, TEFC, NEMA, Premium Efficiency, Medium Voltage
Brands N/A TECO
Power N/A 100 hp
Speed N/A 3600 rpm N/A 1800 rpm N/A 1200 rpm N/A 1200 rpm N/A 900 rpm
Frame Number N/A 444TS N/A 444T N/A 444/5T N/A 444/5T N/A 444/7T
Full Load Efficiency N/A 91.7 % N/A 93.0 % N/A 94.1 % N/A 94.1 % N/A 94.1 %
Full Load Power Factor N/A 86.0 % N/A 79.5 % N/A 81.0 % N/A 81.0 % N/A 74.8 %
Full Load Ampere at 460 Volt (V) Voltage N/A 23.7 A N/A 25.3 A N/A 24.6 A N/A 24.6 A N/A 26.6 A
Approximate Shipping Weight N/A 1,470 lb N/A 2,079 lb N/A 2,903 lb N/A 2,903 lb N/A 2,363 lb
Enclosure N/A Totally Enclosed Fan Cooled (IP55)
Voltage N/A 2300 V4160 V
Phase N/A Three
Continuous Service Factor for 60 Hertz (Hz) Frequency N/A 1.15
Ambient Temperature1 N/A 40 ºC
Elevation2 N/A 3300 ft
Frequency N/A 60 Hz
Inverter Duty N/A 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
Industry Standards and Approval N/A Canadian Standards Association (CSA) NEMA Premium
Shaft Material N/A 1045 Carbon Steel
Applications N/A
  • Pumps
  • Fans and Blowers
  • Compressors
  • Mills
  • Grinders
Features N/A
  • CSA Certified for Class I, Div. 2, for 5000 Frames and above, at 1.15 Service Factor is temperature coded: T3 (125 to 400 HP); T2D (401 to 800 HP); T2B (801 to 900 HP); and at 1.0 Service Factor is T3 only.
  • CSA Certified for Class 1, Div. 2, Groups B, C, and D, for 444 Frames and above, Code T35
  • Standard Features: 100 Ohm Platinum Stator RTD's (2/Phase), Space Heaters (120V)
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments fully Gasketed with NPT Threaded Entrance - F1 Mounted
  • Cast Iron Terminal Box on 444T - 449T Frames
  • Steel Plate Terminal Box on 5000 Frames and Above
  • Bi-Directional Rotation for all 444T - 449T Frames and for 1800 - 900RPM (4 - 8 Pole) 5007 - 6808 Frame Motors and for (4-8 Pole) 5007-6808 Frame Motors
  • 5007 - 6808 Frame 3600RPM (2 Pole) Motors have Counter-Clockwise (CCW) Rotation facing the Drive End
  • Cast Iron Frame and End Brackets
  • Aluminum Die Cast Squirrel Cage Rotor Construction on 444T - 449T Frames
  • Squirrel Cage Copper or Copper Alloy Bar Rotor Construction for on 5007 - 6808 Frames
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Gray - Munsell 7.5B 3.5/0.5
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil PolyrexTM EM
  • Metal Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps
  • Grounding Terminal Inside Main Box and on Motor Foot
  • Stainless Steel Nameplate
  • 6 Leads, with Solderless Lug Terminals
  • Motors are CSA Approved
  • Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2
    • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1. Part 31. An isolation transformer or other method of mitigating common mode voltages from motor terminals must be utilized.
    • Consult Stock Product Specialist for various temp codes on which ratings.
  • 2-Pole motors, 600HP and larger, are Form Wound and Insulated Non-Drive End Bearing
  • Spotface 1/4 -28UNF Tap x 12mm Deep on Top of Both End Brackets with VB300 Vibration Sensor on 5000 Frames and Larger
Note N/A Insulated non-drive end bearing as standard on 2 pole motors 400 HP and larger. Motors are unidirectional, with counter clockwise rotation, facing the drive end, to change please consult factory.
Data subject to change without notice.
Motor service factor is 1.0 when operated on a VFD.
  • 1 Consult a Stock Product Application Specialist for suitability in higher ambient environments, and for variable and constant torque speed ranges.
  • 2 Consult a Stock Product Application Specialist for suitability at higher elevations.