Exit
1011 Athens Street
Gainesville, GA 30501 USA
Gainesville Industrial Electric
AMRCED (MAX-VSP™) NEMA Premium Low Voltage.
Unit of Measure
Items
MAX-VSP™ VSP Series NEMA Premium Three Phase Vertical Solid Shaft Motors

MAX-VSP™ VSP Series NEMA Premium 15 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 254VP Frame Three Phase Vertical Solid Shaft Motor

MAX-VSP™ VSP Series NEMA Premium Three Phase Vertical Solid Shaft Motors

MAX-VSP™ VSP Series NEMA Premium 20 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 256VP Frame Three Phase Vertical Solid Shaft Motor

MAX-VSP™ VSP Series NEMA Premium Three Phase Vertical Solid Shaft Motors

MAX-VSP™ VSP Series NEMA Premium 25 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 284VP Frame Three Phase Vertical Solid Shaft Motor

MAX-VSP™ VSP Series NEMA Premium Three Phase Vertical Solid Shaft Motors

MAX-VSP™ VSP Series NEMA Premium 30 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 286VP Frame Three Phase Vertical Solid Shaft Motor

MAX-VSP™ VSP Series NEMA Premium Three Phase Vertical Solid Shaft Motors

MAX-VSP™ VSP Series NEMA Premium 40 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 324VP Frame Three Phase Vertical Solid Shaft Motor
Description N/A AMRCED (MAX-VSP™) NEMA Premium Low Voltage.
Brands N/A TECO
Power N/A 15 hp N/A 20 hp N/A 25 hp N/A 30 hp N/A 40 hp
Speed N/A 1800 rpm
Frame Number N/A 254VP N/A 256VP N/A 284VP N/A 286VP N/A 324VP
Full Load Efficiency N/A 93.0 % N/A 93.0 % N/A 93.6 % N/A 94.1 % N/A 94.1 %
Full Load Power Factor N/A 83.0 % N/A 83.0 % N/A 85.0 % N/A 86.0 % N/A 86.0 %
Full Load Ampere at 230 Volt (V) N/A 18.2 A N/A 24.3 A N/A 29.4 A N/A 34.7 A N/A 46.3 A
Down Thrust N/A 3350 lb N/A 3350 lb N/A 3350 lb N/A 3350 lb N/A 5700 lb
Dimension BD N/A 10.0 in N/A 10.0 in N/A 10.0 in N/A 10.0 in N/A 16.5 in
Approximate Shipping Weight N/A 309 lb N/A 330 lb N/A 425 lb N/A 465 lb N/A 634 lb
Enclosure N/A Weather Protected Type I (WPI)
Voltage N/A 230 V460 V
Phase N/A Three
Frequency N/A 60 Hz
Continuous Service Factor for 60 Hertz (Hz) Frequency N/A 1.15
Ambient Temperature1 N/A 40 ºC
Elevation2 N/A 3300 ft
Shaft Material N/A 1045 Solid Carbon Steel Shaft
Certification N/A Canadian Standards Association (CSA) European Conformity (CE) Fire Safety National Electrical Manufacturers Association (NEMA) Premium Underwriters Laboratories (UR)
Applications N/A
  • Deep Well Turbine Pumps
  • Irrigation
  • Fire Pumps
  • Fluid Handling Systems
  • Water/Wastewater
Features N/A
  • Inverter Duty (PWM) per NEMA® MG-1 Part 31
  • Dual Column Design Nameplate as Standard; 50 Hz Data 190/380V
  • Standard Features: Ball Type NRR, Drip/Splash Cover, Space Heaters (120V)
  • 5000 Frames and Above include Mounting Provisions for bearing RTD's and Insulated Bearing Housing
  • Class F Insulation with Phenolic Alkyd Resin Varnish
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - Fully Gasketed with NPT Threaded Entrance
  • Cast Iron Conduit Box for F#449VP and Below; Steel Plate Conduit Box for F#5000
  • Counterclockwise (CCW) Rotation; Viewed from Top
  • Cast Iron Frame & End Brackets
  • Aluminum Die Cast Squirrel Cage Rotor Construction for F#449VP and Below
  • Squirrel Cage Copper or Copper Alloy Bar Rotor Construction for F#5000
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color for AMRCED (MAX-VSP™): Blue - Munsell 5PB 3/8
  • Guide Bearings: 254VP - 286VP frames are Grease Pre-packed Double Shielded Bearings (MULTEMP SRL); 324VP - 5009VP frames are Re-Greasable (Mobil Polyrex EM)
  • Thrust Bearings: 254VP - 286VP frames are Re-Greasable Angular Contact (Mobil Polyrex EM); 324VP - 449VP frames are Oil Lubricated Angular Contact; F#5000 and Above with Spherical Roller
  • Oil Requirements for 324VP-405VP - 145 to 175 S.S.U. @100°F
  • Oil Requirements for 444VP-5810VP - 300 S.S.U. @100°F
  • Grounding Terminal Inside Main Box
  • Stainless Steel Nameplate and Rodent Screens
  • 12 Leads (PWS on 230V), Wye/Delta on 230/460V for 210VP-400VP;
    • Suitable for Wye/Delta start at 230V or 460V.
  • 6 Leads (PWS on 230V, Wye D on 460V for 444VP-5810VP)
  • Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2 - 10:1 Variable Torque with NRR. 10:1 C.T., 20:1 VT without NRR Using Braking in VFD
  • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by VFD as stated per NEMA MG-1 Part 31.
Note N/A Fire Pump available as made to order. Fire Pump Certificate complies with ANSI/UL 1004-5. Certificate# 20120717 - EX6569.

Delivery for Fire Pump Duty motor (Catalog Number + FP) is standard 5 - 10 working days after receipt of order if standard motor is in stock;

Painting to Fire Safety Red requirement on Fire Pump Duty type motor can be waived in order to expedite delivery upon request.

Fire Pump Duty Motor pricing includes: adding UL nameplate, restamping original nameplate to new "VSP_FP" catalog number, and Fire Safety Red Paint.

Data subject to change without notice.
  • 1 Consult a Stock Product Application Specialist for suitability in higher ambient environments.
  • 2 Consult a Stock Product Application Specialist for suitability at higher elevations.