Exit
1011 Athens Street
Gainesville, GA 30501 USA
Gainesville Industrial Electric
AESV3W, IEC, IE3 Efficiency
Unit of Measure

Specifications

Brands

N/A TECO

Power

N/A 93 kW125 hp

Speed

N/A 3600 rpm

Frame Number

N/A 280M

Full-Load Efficiency

N/A 95.0 %

Full-Load Power Factor

N/A 89.5 %

Full-Load Ampere at 460 Volt (V) Voltage

N/A 138 A

Approximate Shipping Weight

N/A 615 kg1,356 lb

Enclosure

N/A Totally Enclosed Fan-Cooled (IP55)

Voltage

N/A 230 V460 V

Phase

N/A Three

Frequency

N/A 50 Hz60 Hz

Continuous Service Factor for 50 Hertz (Hz) Frequency

N/A 1.15

Continuous Service Factor for 60 Hertz (Hz) Frequency

N/A 1.0
Ambient Temperature1 N/A 40 ºC
Elevation2 N/A 3300 ft

Shaft Material

N/A 1045 Carbon Steel

Applications

Applications

N/A
  • Fans & Blowers
  • Any Application that Requires IEC Mounting Dimensions
  • Pumps
  • Compressors

Features

Features

N/A
  • Voltage: 230/460V (Usable on 208V) (Suitable for Wye/Delta Starting and part winding on 230V.) Ratings 150 HP and higher are 460V only
  • Class F Insulation
  • Class B Temperature Rise
  • Cast Iron Frame, End Brackets and Main Conduit Box; Rolled Steel Fan Cover
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F3 Mounted (IM1001)
  • Designed for 40ºC Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Blue - Munsell 5PB 3/8
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 80 - 225 (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with MULTEMP SRL for F# 250 and Larger
  • Oil Seal/V-Ring on Both Ends
  • Stainless Steel Nameplate
  • Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2
    • Motor service factor is 1.0 when operated on a VFD.
    • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated by NEMA MG-1. Part 31.
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque
  • 9 Leads for 5 HP & smaller; 12 Leads for 7.5 HP to 125 HP; 6 Leads for 150 HP and Larger
  • Motors are CE Marked

Note

Note

N/A Data subject to change without notice.

Conversion from KG to lbs at 2.20462 and rounded
  • 1 Consult a Stock Product Application Specialist for suitability in higher ambient environments.