Exit
1011 Athens Street
Gainesville, GA 30501 USA
Gainesville Industrial Electric
AFHH, TEFC, NEMA Premium, F3 Convertible
Unit of Measure

Specifications

Brands

N/A TECO

Power

N/A 700 hp

Speed

N/A 900 rpm

Frame Number

N/A 5810B

Full Load Efficiency

N/A 95.6 %

Full Load Power Factor

N/A 81.5 %

Full Load Ampere at 460 Volt (V) Voltage

N/A 841 A

Approximate Shipping Weight

N/A 7,200 lb

Enclosure

N/A Totally Enclosed Fan Cooled (IP55)

Voltage

N/A 460 V

Phase

N/A Three

Frequency

N/A 50 Hz60 Hz

Continuous Service Factor for 60 Hertz (Hz) Frequency

N/A 1.15

Continuous Service Factor for 50 Hertz (Hz) Frequency

N/A 1.0
Ambient Temperature1 N/A 40 ºC
Elevation2 N/A 3300 ft

Shaft Material

N/A 1045 Carbon Steel Shaft

Applications

Applications

N/A
  • Fans and Blowers
  • Pumps
  • Crushers
  • Compressors
  • Mixers
  • Conveyors
  • Any Severe-Duty/ Petro-Chem/Pulp & Paper Application

Features

Features

N/A
  • CSA Certified for Class I, Div. 2, Groups A, B, C, D - Temp Code T2D Minimum
    • Various temp codes apply to ratings. Consult a stock product specialist for accurate code.
  • CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3C Minimum
    • Various temp codes apply to ratings. Consult a stock product specialist for accurate code.
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Cast Iron Frame, End Brackets & Pressed Steel Fan Cover and Plate Main Conduit Box.
  • Oversized Fabricated Steel Main Conduit Box Rotatable in 90 Degree Increments Fully Gasketed with NPT Threaded
  • Entrance - F1 Mounted, Field Convertible to F2 and F3
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments
  • Designed for 40ºC Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation; Except 2 Pole are Counter-Clockwise facing the DE
  • Aluminum Die Cast Squirrel Cage Rotor Construction or Copper Bar Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Light Gray - Munsell N5.0
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM
  • Automatic Grease Discharge Fittings
  • Metal Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps
  • Stainless Steel Nameplate
  • Dual Column Design Nameplate as Standard (60/50 Hz)
  • 6 Leads
  • Motors are CSA Approved
  • Dual Drilled or Tri-Drilled Feet Available on Most Ratings - Longer Frames (i.e. 5009 Drilled also for 5007)
  • Pre-Formed Random Wound, Made of High Pulse Endurance Index Wire, CIV Tested to 2000V/0.1us
  • Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2
    • Motor service factor is 1.0 when operated on a VFD.
    • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1. Part 31.
  • Inverter Duty Speed Range: 10:1 Variable Torque, 3:1 Constant Torque
  • 2-Pole Motors 400 HP and Larger Standard Features: 100 Ohm Platinum Stator RTD's(2/Phase), Space Heaters(120V),and Insulated Non-Drive End Bearings
  • Catalog Numbers Ending in "R" Come Standard with Roller Bearings for Belted Applications.
  • Spotface 1/4-28UNF Tap x 12mm Deep on Top of Both End Brackets with VB300 Vibration Sensor on 5000 Frames and Larger

Note

Note

N/A To check stock or order 575V motors, add "5" to the end of Catalog Number, for example: "EPF20085" for 200 HP, 900 RPM, 575V.

Ratings above 500 HP do not have a NEMA Premium requirement, however do meet NEMA Premium Standards.

Data subject to change without notice.
  • 1 Motor service factor is 1.0 when operated on a VFD.
  • 2 Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1. Part 31.