Gainesville Industrial Electric Co.
Gainesville Industrial Electric Co.
1011 Athens Street
Gainesville, GA 30501

Toll Free: 1-800-457-6210
Local : 770-532-4411
Fax : 770-532-4496
Email: sales@anametelectrical.com
Website: www.gainesvilleindustrial.com
Print Back
AEHHXV/AEHHXU, NEMA Premium
XP Series Three Phase NEMA Premium TEXP Explosion Proof Motors
Unit of Measure
Items XP Series Three Phase NEMA Premium TEXP Explosion Proof Motors
XP0014
XP Series 1 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 143T Frame Explosion Proof NEMA Premium Three Phase TEXP Motor
XP Series Three Phase NEMA Premium TEXP Explosion Proof Motors
XP0016
XP Series 1 Horsepower (hp), 1200 Revolutions Per Minute (rpm), and 145T Frame Explosion Proof NEMA Premium Three Phase TEXP Motor
XP Series Three Phase NEMA Premium TEXP Explosion Proof Motors
XP0018
XP Series 1 Horsepower (hp), 900 Revolutions Per Minute (rpm), and 182T Frame Explosion Proof NEMA Premium Three Phase TEXP Motor
XP Series Three Phase NEMA Premium TEXP Explosion Proof Motors
XP1/52
XP Series 1.5 Horsepower (hp), 3600 Revolutions Per Minute (rpm), and 143T Frame Explosion Proof NEMA Premium Three Phase TEXP Motor
XP Series Three Phase NEMA Premium TEXP Explosion Proof Motors
XP1/54
XP Series 1.5 Horsepower (hp), 1800 Revolutions Per Minute (rpm), and 145T Frame Explosion Proof NEMA Premium Three Phase TEXP Motor
Description N/A AEHHXV/AEHHXU, NEMA Premium
Brands N/A TECO
Power N/A 1 hp N/A 1 hp N/A 1 hp N/A 1.5 hp N/A 1.5 hp
Speed N/A 1800 rpm N/A 1200 rpm N/A 900 rpm N/A 3600 rpm N/A 1800 rpm
Frame Number N/A 143T N/A 145T N/A 182T N/A 143T N/A 145T
Full Load Efficiency N/A 85.5 % N/A 82.5 % N/A 77.0 % N/A 84.0 % N/A 86.5 %
Full Load Power Factor N/A 68.0 % N/A 66.0 % N/A 58.5 % N/A 84.0 % N/A 75.5 %
Full Load Ampere at 460 Volt (V) Voltage N/A 1.61 A N/A 1.72 A N/A 2.08 A N/A 1.99 A N/A 2.15 A
Approximate Shipping Weight N/A 64 lb N/A 93 lb N/A 108 lb N/A 78 lb N/A 80 lb
Enclosure N/A Totally Enclosed Fan Cooled - Explosion Proof (IP55)
Inverter Duty N/A Variable Torque = 3 - 60 Hz
Constant Torque for 140T - 210T Frames = 10 - 60 Hz
Constant Torque for 250T - 320T Frames = 13 - 60 Hz
Constant Torque for 360T - 440T Frames = 16 - 60 Hz
Constant Torque for 5000 Frames = 15 - 60 Hz
Variable Torque for 5000 Frames = 3 - 60 Hz
Voltage1 N/A 230 V460 V
Phase N/A Three
Frequency N/A 60 Hz
Continuous Service Factor for 60 Hertz (Hz) Frequency N/A 1.15
Continuous Service Factor for 50 Hertz (Hz) Frequency N/A 1.0
Ambient Temperature2 N/A 40 ÂșC
Elevation3 N/A 3300 ft
Shaft Material N/A 1045 Carbon Steel
Applications N/A
  • Grain Elevators
  • Applications Where Explosive Gases are Present
  • Pumps
  • Applications Where Explosive Dusts/Grains are Present
  • Blowers
Features N/A
  • Class I, Div. 1, Group C & D and Class II, Groups E, F and G - Temp Code T3B Up to and Including F# 256T
  • Class I, Div. 1, Group D and Class II, Groups E, F and G - Temp Code T3B for F# 284T and Larger
  • UL File: E84757
  • CSA File: #64671
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Dual Drilled Back Feet on 447/9 and 5007/9 Frames
  • Bi-Directional Rotation
  • Cast Iron Frame, Fan Cover, End Brackets and Main Conduit Box
  • Capable of Withstanding Explosion Force as Required by UL
  • Stainless Steel Breather Drains with Bronze Filters (For Horizontal Mount Only)
  • Aluminum Die Cast Squirrel Cage Rotor Construction through 449 Frame; Fabricated Copper Bar on 5000 Frame
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Blue - Munsell 5 PB 4.5/2
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil PolyrexTM EM for F# 280TS and Larger
  • Bronze Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger
  • Stainless Steel Nameplate
  • Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2
    • Motor Service Factor is 1.0 when operated on a VFD.
    • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG-1. Part 31.
    UL Listed for Inverter Duty
  • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of up to 2200 Volts
  • 9 Leads for 5 HP and Smaller
  • 12 Leads for 7.5 HP to 125 HP
  • 6 Leads for 150 HP and Larger
Note N/A Data subject to change without notice.
Extras/Modification options are limited on TEXP Products. Available options: M2X, M8B, M11(449T frame and below, maybe all),M16; M8; M18A;M15; M14; M21A; M22.
Industry Standards and Approval N/A Canadian Standards Association (CSA) ee CCOO2A NEMA Premium Underwriters Laboratories
  • 1 Available in 575V. TWMC carries minimal 575V stock; please check availability to ensure required motors are in stock. Ratings may be available from our Canadian warehouses and/or our factory. Pricing and leadtime may vary.
  • 2 Consult a Stock Product Application Specialist for suitability in higher ambient environments.
  • 3 Consult a Stock Product Application Specialist for suitability at higher elevations.