AEEHNH, (MAX-VHP™) NEMA Premium
Unit of Measure

Specifications

Brands

N/A TECO

Power

N/A 600 hp

Speed

N/A 1200 rpm

Frame Number

N/A 5810VP

Full Load Efficiency

N/A 95.8 %

Full Load Power Factor

N/A 81.7 %

Full Load Ampere at 460 Volt (V) Voltage

N/A 717 A

Approximate Shipping Weight

N/A 7,260 lb

Down Thrust

N/A 20,200 lb

Dimension BD

N/A 30.0 in

Enclosure

N/A Totally Enclosed Fan Cooled (IP55)

Voltage

N/A 230 V460 V

Phase

N/A Three

Service Factor for 60 Hertz (Hz) Frequency on Continuous Sine Wave Power

N/A 1.15

Ambient Temperature

N/A 40 ºC

Elevation

N/A 3300 ft

Applications

Applications

N/A
  • Deep Well Turbine Pumps
  • Irrigation
  • Water/Wastewater

Features

Features

N/A
  • Voltage: 230/460V (Usable on 208V); 150HP and Larger is 460V Only
  • 230/460V Motors Suitable for Partial Winding Start (at 230V Only)
  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous on Sine Wave Power)
  • CSA Certified for Class I, Div. 2, Group B, C, D - Temp Code T3 Minimum
  • Inverter Duty (PWM) per NEMA® MG-1 Part 31 at 1.0 Service Factor
  • Dual Column (60/50 Hz) Design Nameplate as Standard; 50 HData 190/380V at 1.0 S.F.
  • Standard Features: Non-Sparking Ball Type NRR, Drip/Splash Cover, Space Heaters (120V)
  • 5000 Frames and Above also include Mounting Provisions for bearing RTD's and Insulated Bearing Housing
  • CSA Certified for Class I, Div. 2, Groups B, C, D; Temp Code T3 minimum
  • Class F Insulation with Phenolic Alkyd Resin Varnish
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - Fully Gasketed with NPT Threaded Entrance
  • Cast Iron Conduit Box for F#449TP and Below; Steel Plate Conduit Box for F#5000
  • Designed for 40?C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Counterclockwise (CCW) Rotation; Viewed from Top
  • Cast Iron Frame & End Brackets
  • 1045 Solid Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Blue - Munsell 5PB 3/8
  • Guide Bearings: 254VP - 286VP frames are Grease Pre-packed Double Shielded Bearings (MULTEMP SRL) 324VP - 5009VP frames are Re-Greasable (Mobil Polyrex EM)
  • Thrust Bearings: 254VP - 286VP frames are Re-Greasable Angular Contact (Mobil Polyrex EM); 324VP - 449VP frames are Oil Lubricated Angular Contact; F#5000 and Above with Spherical Roller
  • Oil Requirements for 324VP-405VP - 145 to 175 S.S.U. @100°F
  • Oil Requirements for 444VP-5810VP - 300 S.S.U. @100°F
  • Grounding Terminal Inside Main Box
  • Stainless Steel Nameplate and Rodent Screens
  • 12 Leads (PWS on 230V) on 254VP - 405VP;
  • 6 Leads on 444VP to 449VP; 5000 Frames and Above with Connection Studs
  • Suitable for Inverter Use per NEMA MG-1 Part 31.4.4.2 - 10:1 Variable Torque with NRR. 10:1 C.T., 20:1 VT without NRR Using Braking in VFD
  • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by VFD as stated per NEMA MG-1 Part 31
  • Suitable for Wye/Delta start at 230V or 460V.
  • Suitable for Wye/Delta start at 460V.

Note

Note

N/A Suitable for Wye/Delta start at 230V or 460V.
Suitable for Wye/Delta start at 460V.
In order to confirm the TWMC standard coupling size is suitable for customer requirements or to select an alternate coupling size. Required coupling size must be noted on all vertical hollow shaft motors orders. Coupling will be changed out prior to shipping if a non-TW standard coupling size is needed.